Scxi-1162hv. 1 1 /7 SP1 2 (32-bit 3 and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ and IC-317x controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI. Scxi-1162hv

 
1 1 /7 SP1 2 (32-bit 3 and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ and IC-317x controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NIScxi-1162hv Application Software 1 Versions Supported by NI-DAQmx 18

1支持下列操作系统:. She is named after the city of. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 6 software. You can, therefore, easily integrate SCXI‑1162HV modules into existing SCXI systems without additional DAQ devices or cabling. 32-Channel, Input (240 V), Digital I/O Module for SCXI —The SCXI‑1162HV is an optically isolated digital input module for SCXI. 2. scxi-1302. 32-channel isolated ac/dc digital input module (43 pages) I/O Systems National Instruments SCXI-1102 Calibration Procedure. 2。. SCXI-1162HV. The terminals labeled GND are not used on the SCXI-1162. It has isolated input channels with 300 Vrms working isolation as well 12 programmable gain settings. SCXI-1162HV User Manual - National Instruments. . . SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient. The SCXI-1162 interfaces directly to field digital logic input signalsNI SCXI-1600 : module USB Remarque importante : Hotfix de Microsoft pour les périphériques DAQ USB et Windows XP Si vous utilisez NI-DAQmx avec un périphérique DAQ USB sous Windows XP, vous devez installer le correctif logiciel de Microsoft indiqué dans l'article 969238 de la Base de connaissances de Microsoft . Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. Product Parameters: Voltage. discontinued by manufacturer, terminal block, feed through, 777687-02. I know the inputs are tied together. Refer to the NI website for any updates to the current NI-DAQmx readme. Buenas tardes: Si alguien puede ayudarme en el siguiente problema lo agradecería enormemente: Se trata de una aplicación inicialmente construida con CVI 5. 18 MB. Part Number: 182638-01, 182638C-01, 182638E-01, 185628C-01, 182628E-01, 182638D-01, 776572-62HThe SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. These signals. This file contains important information about NI-DAQmx, including installation instructions and known issues. . 如应用程序使用. PXI-6529: 48. connections to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules. 1支持下列操作系统: Windows 10(32位和64位) Windows 8. SCXI-1162HV User Manual - National Instruments. This chapter also includes specifications and connection instructions for the signals on the SCXI-1122 connectors. Extended I/O Connector. The SCXI-1162HV can monitor TTL level inputs as well as sense the presence of high-voltage AC and DC signals. com ¥ ni. The following operating systems are supported by NI-DAQmx 18. 00. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. 0. 1: Windows 10/8. You can cable the TBX-1326 to the SCXI module with the SH48-48-B shielded cable. info and type rdfis5 to order a configured PXI/SCXI combination chassis. Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01. . We are using PXI 6229 as communicating card. The target and host are running LV Real-Time 8. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI-1162HV User Manual - National Instruments. The following operating systems are supported by NI-DAQmx 17. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. kualitas tinggi NI SCXI-1000 SCXI-1162HV SCXI-1180 SCXI-1163R 1302/1326 * ASLI * dari Cina, otomatisasi dcs Produk, dengan kontrol kualitas yang ketat modul dcs pabrik, menghasilkan kualitas tinggi modul dcs Produk. sales@changxinplc. El SCXI‑1162HV también puede operar en modo paralelo cuando se cablea directamente a un dispositivo de E/S digital. SCXI Terminal Blocks 3 BUY ONLINE at ni. An SCXI-1162HV module was used for the 32 digital sensor inputs. All Manuals. Each channel also includes a. 지원되는 OS. NI-DAQmx自述文件更新. SCXI-1162HV SCXI1162HV: 5998-01-567-9476: Circuit Card Assembly: End Item Identification: Mobile engine test system (mets) 4920-99-284-3113, T56-A-15 (engine C-130) Special Features: 32 ch high-voltage isolated digital input module: 64667SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. It has 32 channels which are arranged into 8 isolated banks of four input lines each. com. NI SCXI-1600 USB module; Important Notice: Microsoft Hotfix for USB DAQ Devices and Windows XP. +5 to +10 V Digital Logic Levels for the SCXI-1162 Digital logic levels for the SCXI-1162HVTerminal for SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R; Easily Accessible Screw Terminals for Field Wiring; Shielded, Low-Noise Cabling. National Instruments SCXI-1326 SCXI Terminal Block Manuals, Datasheets, Drivers, Links. SCXI-1162HV NI 32-Channel, Isolated AC/DC, Digital Input Module, NI, SCXI-1162HV NI 32-Channel, Isolated AC/DC, Digital Input Module The NI SCXI-1162HV (Part Number: 776572-62H) has 32 channels of optically-isolated digital inputs, which are organized into eight separate banks of four input lines each. We are currently using a National Instruments DAQ - SCXI-1162HV and our current configuration is PXI. 0では、以下のオペレーティングシステムがサポートされます。. SCXI-1162HV, SCXI-1163, SCXI-1163R SH48-48-B Ð High-voltage 250 VDC TBX-1328 SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126 SH32-32-A Sockets for current. Overview 60M100-00 Framework interface module. 3 min read. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. NI SCXI-1126 isolated frequency input channel module; NI SCXI-1127 and SCXI-1128 relay modules ; NI SCXI-1129 high-density matrix module; NI SCXI-1140 track-and-hold module; NI SCXI-1141, SCXI-1142, and SCXI-1143 Lowpass Filter Modules ; NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1190 RF switch module National Instruments SCXI-1102C 32-Channel Thermocouple Amplifier Module. GE General Electric DS200CPCAG1ABB Gas Turbine Card IN STOCK NI SCXI-1162HV Optical Isolation Digital Input Module from the United States Powerfully Supplied GE General IS200EROCH1ABB Inventory ABB…本文件包含NI-DAQmx的重要信息,包括安装指南和已知问题。. The 16 DC outputs were controlled with an SCXI-1163R. 1. ni scxi-1600 usb 모듈 중요한 알림 사항: USB DAQ 디바이스 및 Windows XP를 위한 Microsoft Hotfix Windows XP에서 USB DAQ 디바이스와 함께 NI-DAQmx를 사용하는 경우, Microsoft Knowledge Base 969238 의 설명과 같이. NI-DAQmx 15. 1。SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01ni scxi-1600 usbモジュール 重要なお知らせ: USB DAQデバイスおよびWindows XP用Microsoft Hotfix Windows XPにNI-DAQmxをインストールしてUSB DAQデバイスを使用する場合は、 技術サポートデータベース(969238) に記載されているMicrosoft Hotfixをインストールすることをお勧めし. SCXI-1001: PXIe-1065: cDAQ 9178 cDAQ. 4-12. Buenas tardes: Si alguien puede ayudarme en el siguiente problema lo agradecería enormemente: Se trata de una aplicación inicialmente construida con CVI 5. ここでは、修正された問題をすべて網羅しているわけでは. There will be some analog input and a small number of digital outputs being handled during this acqui. E-mail: [email protected]: Windows 10/8. 1 No connects appear on pins 20 through 22 of devices that do not support AO or use an external reference. Calibration for SCXI devices is supported only in Traditional NI-DAQ. 5, a delay of 20 µs was added to the fastest possible channel conversion rate on an SCXI chassis connected to a 16-bit or 18-bit E or M Series device. SCXI-1166, 32 Channel, Non-Latching Relays, General-Purpose Switch Module. This file contains important information about NI-DAQmx, including installation instructions and known issues. Default NI-DAQmx Counter Terminals. I know that both 11. 4 days ago. EN. SCXI-1162HV, SCXI-1163, SCXI-1163R SH48-48-B – High-voltage 250 VDC TBX-1328 SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126 SH32-32-A Sockets for current. The following operating systems are supported in NI-DAQmx 16. The National Instruments SCXI-1326 is designed for high-voltage digital input or digital output applications. 01 and NI. . 操作系统支持. 0新增对LabVIEW 2018和LabVIEW NXG 2. 6. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. NI SCXI-1162 32通道高压数字输入模块 SCXI-1162HV 库存. 1は、イーサネットおよびワイヤレスCompactDAQシャーシ上のNI-XNETモジュールが正しくロードされない問題を. Esta se ha reconvertido con CVI 7. 0不再支持Microsoft Windows 7 RTM、Windows Vista、Windows XP和Windows Server 2003. 3221366881@qq. Windows Embedded Standard 7 、SP1(CompactDAQコントローラ上). NI-DAQmx 16. 1: Windows 10 (32-bit and 64-bit) Windows 8. This module senses the presence of a wide range. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. 6. It allows for. 지원되는 OS. SCXI-1162HV User Manual - National Instruments. . NET 4. NI-DAQmx 15. I've configured with MAX two channels the first is the channel to Dev1 port PA0, teh second is the channel to Dev1_SC1_MD1 DIN1. The SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. SCXI-1321 Terminal Block. --. It sounds like your 1162HV is working correctly. Calibration for SCXI devices is supported only in Traditional NI-DAQ. SCXI-1162HV User Manual - National Instruments. 1 1 /7 SP1 2 (32-bit and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI software installs. 2. EN. The optical isolation of the SCXI-1162. Supported Operating Systems. 4-10 Figure 4-5. 6: Windows 10/8. NI SCXI-1162HV. The SCXI-1162HV works with National. Features: 48-Screw Terminals for Signal Connections. SCXI Model Number: PXI Model Number: C Series Model Number SCXI-1000: PXIe-1071: cDAQ 9174 cDAQ 9184 SCXI-1000DC: PXIe-1071 PXIe-1082 (782946-01) cDAQ 9174 cDAQ 9184: Choose the PXIe-1071 if the application requires four PXIe slots; however, if DC power is a more important feature choose the PXIe-1082 (DC). +86-17735379951SCXI-1162HV User Manual - National Instruments. Whats app:+86 17750010683. It provides a convenient method for connecting and. It is an ideal solution for large-channel-count temperature or voltage applications. Windows Server 2008 R2 P1(64ビット、サーバコアロールでは. Website: GE General. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. The <strong>SCXI</strong>-<strong>1162HV</strong> is a module for sensing the presence of AC or DC voltages wherehigh common-mode voltages may be. com. Computer Four small screws (included in this kit) Two cable tie wraps SCXI-1353 Shielded Cable Installation Guide. Find many great new & used options and get the best deals for National instruments NI SCXI-1162HV 182638E-01 SHIP at the best online prices at eBay! Free shipping for many products!NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module; NI SCXI-1530 and SCXI-1531 modules for accelerometers and microphones; NI SCXI-1540 linear variable differential transformers (LVDT) module;The SCXI-1000 chassis is capable of holding up to four modules while the SCXI-1001 can hold up to 12. Skype:+86 17750010683. The optical isolation of the SCXI‑1162HV eliminates ground-loop problems and isolates the host computer from damaging voltages. National Instruments SCXI-1127- 30 W, 60 VA maximum switching power for each channel. The terminal block has 48 screw terminals for easy signal connections. SCXI-1162HV User Manual - National Instruments. National Instruments will, at its option, repair or National Instruments SCXI-1162HV 32-Channel Isolated Digital Input Module Part Number: 182638-01, 182638C-01, 182638D-01, 182638E-01, 185628C-01, 182628E-01 Show More Description Re: PXIe-6361 does not recognize SCXI modules on SCXI-1000. National Instruments SCXI-1326 SCXI Terminal Block Manuals, Datasheets, Drivers, Links. 1的支持。. SCXI-1305 Terminal Block Figure 1. 5. SCXI modules controlled the stand. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. National Instruments SCXI-1162- TTL/CMOS: Call: SCXI-1162HV: National Instruments SCXI-1162HV- 240 V: In Stock Ships Today: SCXI-1163: National. 操作系统支持. Biblioteca de Soporte. NI-DAQmxの既知の問題の最新リストについては、. Share: Description Consultation price Reviews (0)SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient method for connecting and disconnecting signals to your system. One of the 1162HV is the communication module between the pci card and the rack. SCXI-1310 Connector and Shell Assembly Figure 2. The NI SCXI-1162HV features 32 Channels and an Input Current Limiting of 1 mA. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. Supported Operating Systems. SCXI-1102C, SCXI-1124, SCXI-1162HV modules TC-2095, TBX-1303, TBX-1325, TBX-1326 terminal blocks. TBX-1326 SCXI-1162, SCXI-1162HV, SCXI-1163, SCXI-1163R SH48-48-B – High-voltage 250 VDC TBX-1326 high-voltage terminal block with the SCXI-1162/HV, SCXI-1163, and SCXI-1163R modules. The National. Contents. FIM card MOOG — D136-001-007 Servo valve, controller, module NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module,. ni scxi-1600 usb模块 重要通知:用于USB DAQ设备和Windows XP的Microsoft修补程序 如在Windows XP平台上使用USB DAQ设备和NI-DAQmx,建议安装 Microsoft知识库文章969238 中的Microsoft修补程序。You are using an SCXI-1530, SCXI-1531, or SCXI-1540 device with accelerometer, linear-voltage differential transformer (LVDT), or rotary variable-differential transformer (RVDT) virtual channels, which are not supported by NI-DAQmx. The optical isolation also alienates the host device from damaging voltages. SCXI-1127. Find many great new & used options and get the best deals for National instruments NI SCXI-1162HV 182638E-01 SHIP at the best online prices at eBay! Free shipping for many products! NI SCXI-1141, SCXI-1142, and SCXI-1143 lowpass filter modules ; NI SCXI-1160 16-SPDT general-purpose relay module; NI SCXI-1161 8-SPDT power relay module; NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module The SCXI-1000 chassis is capable of holding up to four modules while the SCXI-1001 can hold up to 12. NI-DAQmx 19. Part Number: 183087H-03, 183087K-03L, 183087G-03, 183087F-03. NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module; NI SCXI-1530 and. are not included with this equipment unless listed in the above stock item description. We have a great online selection at the lowest prices with Fast & Free shipping on many items!SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01NI工程師你好,我想問一下關於OVDER TRACKING的一些相關的東西 我是初學者有沒有一些範例能參考看看。我們是用LABVIEW7. Chapter 4, Theory of Operation, contains a functional overview of the SCXI-1122 module and explains the operation of each functional unit making up the. SCXI hardware is managed through programmatic DAQ commands to accommodate both slow and fast acquisition modes. 5; LabVIEW: 2015, 2016, 2017, and 2018: LabVIEW Real-Time Module: 2015, 2016, 2017, and 2018: LabVIEW NXGGet the best deals for scxi-1162 at eBay. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. 0及后续版本无法在不支持的操作系统上安装或运行。. ni scxi-1600 usb模块. Voltage Input Module for SCXI. . Überblick. EN. cabled device : nil. Product Name: SCXI-1162HV Module Product Description: The SCXI-1162HV module is a high-voltage multiplexer module designed for use with the SCXI platform. This guide describes how to use and install the SCXI-1326 high-voltage terminal block with the SCXI-1162, the SCXI-1163, the SCXI-1162HV, and the SCXI-1163R modules. The SCXI-1162HV Digital I/O Module can monitor TTL level inputs and sense the existence of high-voltage AC and DC signals. EN. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. . I have installed a DAQCard-6533 wired to SCXI-1000 chassis and one board SCXI-1162HV. NI-DAQmx 18. EN. The question is what is the best method for reading these four ports. This module is controlled by the DAQ device serially in multiplexed-mode over the SCXIbus making it easy to integrate multiple modules into existing SCXI systems without additional DAQ devices or cabling. It has a cold-junction compensation sensor for temperature measurements and multiple gain ranges with a 10 kHz cut-off frequency filter. 0 adds support for LabVIEW 2016. for 1324. The SCXI-1162HV User Manual is organized as follows: • Chapter 1, Introduction, describes the SCXI-1162HV; lists what you need to get started with your SCXI-1162HV; describes. Signal Name. The National Instruments TBX-1326 is a high-voltage terminal block with 48 screw terminals for the SCXI-1162 Series and SCXI-1163 Series modules. Categories: NI. 32-Channel, ±10 V, 10 kHz Filter, Voltage Input Module for SCXI —The SCXI‑1102C is designed for the signal conditioning of thermocouple, millivolt, volt, and current signals. Supported Operating Systems. . The resulting reduction in the number of submarine assets and supporting maintenance dollars jeopardize the Navy’s ability to complete their complex mission requirements. The SCXI-1326 is high-voltage and has 48 screw terminals for signal connections to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules. For example, you can use an SCXI. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. Between those two values is undefined. 32 outputs were required forPre-owned. 1 addresses an issue in which incorrect data is returned by multi-device tasks run on the NI cDAQ-9179 with specific module configurations. The NI SCXI-1326 (Part Number: 777687-26) is a High-Voltage Screw Terminal Block with supports to link to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules’ front connector. The NI SCXI-1326 (Part Number: 777687-26) is a High-Voltage Screw Terminal Block with supports to link to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules’ front connector. NI-DAQmx 17. NI-DAQmx 17. The terminal block has 48 screw terminals for easy signal connections. I use the digital data logger to log the input from lines 4 and 7 and the digital da. Digital SCXI Modules In addition to analog SCXI modules, National Instruments produces a variety of digital modules—the SCXI-1160, SCXI-1161, SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R. NET 4. 1. com or CALL 800 813 3693 (U. EN. The NI SCXI-1326 (Part Number: 777687-26) is a High-Voltage Screw Terminal Block with supports to link to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules’ front connector. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. 1 1 /7 SP1 2 (32-bit and 64-bit) Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers) Windows Server 2012 R2 1 (64-bit) Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role) 1 NI software installs VC2015 Runtime and . The SCXI-1162HV by National Instruments is a Digital I/O Module for SCXI. Each channel also includes a. 4-10 Figure 4-5. Windows 7(32位和64位). SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. We have 2 National Instruments SCXI-1162HV manuals available for free PDF download: Getting Started, User Manual National Instruments SCXI-1162HV Getting Started (158. Trendmaster Pro is an innovative online vibration monitoring system that links hundreds of permanently. National Instruments SCXI-1163R 32-Channel Optically Isolated Solid-State Relay Switch. CTR 0 SRC. arinc & 1553 . . Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. TBX-1326 high-voltage terminal block with the SCXI-1162/HV, SCXI-1163, and SCXI-1163R modules. Mobile/ WeChat/ WhatsApp:+86 13365909307. 0: Windows 10/8. About This Manual. SCXI-1129. E-mail: simondcsplc@foxmail. Set the voltage selection tumbler to the correct voltage for your. 2016年起NI-DAQmx将不再支持Microsoft Windows Vista、Windows XP和Windows Server 2003. 5: Windows 10/8. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 1. For High-Voltage Digital Input or Digital Output Applications. 4 days ago. 1 1 /7 SP1 2 (32-bit 3 and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI. The SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. Website: GE General Electric. Each SCXI chassis contains an 1162HV module for reading high voltage digital signals and an 1102 thermocouple module connected to a 6251 M Series MIO DAQ card to read up to 32 thermocouples. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. Victoria. GE General Electric DS200CPCAG1ABB Gas Turbine Card IN STOCK NI SCXI-1162HV Optical Isolation Digital Input Module from the United States Powerfully Supplied GE General IS200EROCH1ABB Inventory. DAQ Traditional NI-DAQ TM User Manual Version 7. EN. The NI DAQ driver software can be executed for operating the SCXI-1162HV. SCXI-1162, SCXI-1162HV Typical for 25 ˚C unless otherwise noted. In Figure 4, all switches are shown in the off position. It has isolated input channels with 300 Vrms working isolation as well 12 programmable gain settings. The SCXI-1162HV is an optically isolated module, so ground loop issues are minimized by the isolation. Industries. Windows Server 2012 R2 (64ビット). 1 addresses issues with NI-XNET modules on Ethernet and wireless CompactDAQ chassis not loading properly. NI-DAQmx 17. Driver Version Naming Changes. The SCXI‑1162HV. This scxi 1001 has 5x scxi 1163R modules and 2x scxi 1162HV modules. The other four were input with an SCXI-1121 to allow an input that required excitation. . properly. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. The terminals labeled GND are not used on the SCXI-1162. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. SCXI-1162HV User Manual - National Instruments. The SCXI-1162HV senses the presence of a wide range of AC or DC signals, from digital logic level signals up to 240 VAC/VDC signals. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01The SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. Academic and Research; Aerospace, Defense, and Government;. ·. SCXI-1162HV module:The SCXI-1162HV is a module for sensing the presence of AC or DC voltages where high common-mode voltages may be present. Für die Installation von NI-DAQmx 19. HMCS. The. 1 1 (32-bit and 64-bit); Windows 7 SP1 2 (32-bit and 64-bit); Windows Embedded Standard 7 2, SP1 (32-bit and 64-bit); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1, SP1 (64-bit, not supported on. It is an ideal solution for large-channel-count temperature or voltage applications. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. The terminal block has 48 screw terminals for easy signal connections. The NI SCXI-1326 (Part Number: 777687-26) is a High-Voltage Screw Terminal Block with supports to link to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules’ front connector. 1. The following operating systems are supported by NI-DAQmx 18. E-mail: simondcsplc@foxmail. ⑥ Does it include tariffs? It does not include any. This file contains important information about NI-DAQmx, including installation instructions and known issues. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI-1162HV User Manual - National Instruments. NI-DAQmx 17. . Re: PXIe-6361 does not recognize SCXI modules on SCXI-1000. 6. 2015年10月版. The module is programmed by the DAQ device serially over the SCXIbus. NI SCXI-1600 : module USB Remarque importante : Hotfix de Microsoft pour les périphériques DAQ USB et Windows XP Si vous utilisez NI-DAQmx avec un périphérique DAQ USB sous Windows XP, vous devez installer le correctif logiciel de Microsoft indiqué dans l'article 969238 de la Base de connaissances de Microsoft . 0 has the following requirements: 1 GHz or faster 32-bit (x86) or 64-bit (x64) processor. In Stock. NI-DAQmx 18. The SCXI-1162HV is designed for 240 VAC/VDC input. Warning: The TBX-1326 and SH48-48-B limit the maximum working common-mode voltage between banks or between banks and earth ground to 250 V rms maximum. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。Operating System Support. The city has a population of 91,867, and the. The optical isolation of the SCXI‑1162 eliminates ground-loop problems and isolates the. scxi-1326 でvcc とラベル表示されている端子は、scxi-1162hv また はscxi-1163r と一緒に使用できません。gnd とラベル表示されている 端子は、scxi-1162 では使用しません。ネジ留め式端子は6 端子一組の合 計8 組が配置されています。各組ごとに絶縁されています。各. 1 /7 SP1 (32ビットおよび64ビット. The NI SCXI-1326 (Part Number: 777687-26) is a High-Voltage Screw Terminal Block with supports to link to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules’ front connector. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01Hello, Trying to keep it short, we are trying to get Labview 5. Important Information Warranty Your DAQ hardware is warranted against defects in materials and workmanship for a period of one year from the dateThe following operating systems are supported by NI-DAQmx 17. The NI SCXI-1162 (Part Number: 776572-62) is an optically isolated Digital Input Module, which can interface to field digital logic signals where common-mode voltages may exist, such as TTL and CMOS. 6; LabVIEW: 2015, 2016, 2017, and 2018: LabVIEW Real-Time Module: 2015, 2016, 2017, and 2018: LabVIEW NXGNI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module; NI SCXI-1530 and SCXI-1531 modules for accelerometers and microphones; NI SCXI-1540 linear variable differential transformers (LVDT) module;SCXI-1122 module via the SCXI-1122 front connector and rear signal connector. This Terminal Block is also well-suited for. NI-DAQmx 15. Application Software 1 Versions Supported by NI-DAQmx 18. 0 para Win95. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. Find the National Instruments SCXI-1324 at our website: Click HERE. · scxi-1100: 设置跳线 w5 到1-2位置 (对于版本c模块或者更新的设备,同样设置跳线w9 到1-2位置). SCXI-1162HV User Manual - National Instruments. We have a great online selection at the lowest prices with Fast & Free shipping on many items!SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. Leer más Mostrar Menos. Another type of SCXI module is digital input and output modules. com. 531X303MCPARG1 F31X303MCPAPG100600. com. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. このファイルには、インストール手順、既知の問題など、NI-DAQmxに関する重要な情報が記載されています。. NI-DAQmx 15. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский български العربية UnknownSCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI-1162HV User Manual - National Instruments. Find the National Instruments SCXI-1317 at our website: Click HERE. Windows 10/8. The SCXI-1162HV senses the presence of a wide range of AC or DC signals, from digital logic level signals up to 240 VAC/VDC signals.